(针对新混凝土或新水磨石基面)
养护期:28天以上,底层做过防水处理
粉光强度:300PSI(210kgf/cm 或C25)以上
含水率:8%以下
相对湿度:55%以下
平整度:2-3mm/2M以内
The requirements of the raw floor before construction
(For the fresh cement or terrazzo ground)
Maintaining period: over 28 days and no water any more (except the
ground above the first floor)
Concrete strength: above 300PSI(210kgf/cm2 or C25)
Free water/cement ratio: under 8%
Relative humidity: under 55%
Level degree: within 2~3mm/2M
气候条件
空气湿度高于85%时,或气温在50℃以下,应避免施工。或改用其它低温耐湿产品。
Clim ate conditions
To avoid the surface of the floor dimming, whitening or not easy to
dry, the construction shouldn`t be performedin the following
conditions: rainy day、the air relative humidity above 85% or
temperature under 10 degree. Another anti-low temperature and
moisture-resistant material is alternative under the frustrated
construction conditions.
场地准备
施工现场须清走所有杂物,最好避免交叉施工、禁止无关人员出入。
Ground preparation
Cleaning all the sundries in the construction field; Avoiding cross
construction; Prohibiting all the irrelative from entrancing in.
地面预处理
地面如有少数地方潮湿,施工必须用瓦斯枪强制干燥;如有油污等,需用专用洗涤剂作清洁处理。
Ground pre-processing
If there are few damp spots, heating the ground with the gas-sprayer
to make them dry. If there are oils, the special detergent should be
used to clean.
|
|